Gen 1.3: Replace Remote Receiver

The primary cause of failure in the remote receiver is water entering the connection with the CAT 5 cable.  When replacing the remote receiver, we advise also replacing the receiver cable and antenna. Time:  5 minutes Tools: Phillips screwdriver Parts: Gen 1.3/3...

Gen 1.3: Replace Pressure Gauge

Time:  15 minutes Tools: 15 mm wrench channel lock pliers or crescent wrench 5/16″ nut driver Teflon tape Parts: Replacement pressure gauge kit, including adapter rings (#10978) straight female connector 1/4″ Threaded x 1/4″ PTC (# 10119) 1. ...

Gen 1.3: Replace Pump

Time:  15 minutes Tools: Phillips head screwdriver Parts: Gen 3/1.3 Brass Pump Assembly, including fittings – (#21005) 1.  Reposition controller and plastic cover.  See Gen 1.3:  Access components by Repositioning Cover. 2.  Remove existing pump A.  Using...