by homerjon_mistaway | Dec 31, 1969 | Gen 1.3 – Setup
Leak Detection is an option – usually factory installed: Enables Gen 1.3 to detect a leak in the nozzle circuit and suspend misting. Enables Gen 1.3 to accurately report the level of remaining solution in the drum See Gen 1.3: Level Display Required to enable...
by homerjon_mistaway | Dec 31, 1969 | Gen 3 - Troubleshooting
What is ERR3? ERR3 is displayed when the batch tank fill volume is significantly greater than expected. Most Common Cause: leak in the nozzle circuit. Other Potential Causes: System Setup does not reflect installed system – 1) more nozzles installed than...
by homerjon_mistaway | Dec 31, 1969 | Gen 3 Repairs
The pump is located in the back left corner of the unit. The sidewalls must be removed to access it. Time: 20 minutes Tools: Phillips head screwdriver 3/4″ wrench Parts: Gen 3/1.3 Brass Pump Assembly, including fittings (#21005) 1. Remove...
by homerjon_mistaway | Dec 31, 1969 | Specs, Safety & Warranty
In 2006, the National Pest Management Association (NPMA), gathered a workgroup to develop guidelines to promote responsible practices by misting system industry participants. The workgroup included a number of misting industry participants (including MistAway),...
by homerjon_mistaway | Dec 31, 1969 | Controller & Remote
Gen 1.3 SET-UP MENU REM Set the duration for mists triggered by the remote transmitter. (Values from OFF to 120 seconds) LRN Program unit to recognize a specific remote transmitter. Hold down Green ► button for 5 seconds and then press a button on the remote...