Gen 3: Replace Gray Plastic Flow Meter

The flow meter is the gray component with the red and black leads located against the back right wall of the unit.  This component was used in Gen 3 units sold from 2007 – 2011.  It is no longer available and must be replaced with a brass flow meter.  This also...

Installing the Nozzle Circuit – Training Videos

The first two videos in this article introduce the five “Universal Truths” of nozzle installation and what tools will be handy to have when you install your nozzle circuit.  Those are followed by two videos that will provide technique and tips for installing nozzles...

Controller: Setting AUTO MIST Cycles

Set AUTO MIST Cycles 2 – 3 scheduled mists of 30-60 seconds in duration is common.  See Mist Schedule and Duration for field standard frequency, duration and mist times. CYCLES Menu Blinking C# identifies each automatic mist cycle with current mist duration and...

Gen 1.3: Replace Pressure Gauge

Time:  15 minutes Tools: 15 mm wrench channel lock pliers or crescent wrench 5/16″ nut driver Teflon tape Parts: Replacement Pressure Gauge Assembly – Includes Gauge and Fitting (SKU 21037) 1.  Reposition controller and plastic cover.  See Gen 1.3:  Access...